OFNR Riser (PVC)
Optical Fiber Nonconductive Riser (OFNR) cable is intended for vertical runs between floors or non-plenum applications.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
N/A | .275 |
Type. Atten. (dB/km) | 3.0/1.0 |
Max. Atten. (dB/km) | 3.75/1.5 |
Bandwidth (Mhz*km) Corning# | 220/500 InfiniCor 300 385/500 InfiniCor 1000 |
Diameter (mm) | 6.3 |
Pull Load (N) Install/Operate |
1800/600 |
Bend Radius (cm) Install/Operate |
9.8/6.5 |
Buffer Size (um) | 900 |
Storage Temp. (°C) | -40 / +85 |
Operating Temp. (°C) | -20 / +85 |
OFNP Plenum
Optical Fiber Nonconductive Plenum (OFNP) cable is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
N/A | .275 |
Type. Atten. (dB/km) | 3.0/1.0 |
Max. Atten. (dB/km) | 3.75/1.5 |
Bandwidth (Mhz*km) Corning# | 220/500 InfiniCor 300 385/500 InfiniCor 1000 |
Diameter (mm) | 6.3 |
Pull Load (N) Install/Operate |
1800/600 |
Bend Radius (cm) Install/Operate |
9.8/6.5 |
Buffer Size (um) | 900 |
Storage Temp. (°C) | -40 / +85 |
Operating Temp. (°C) | -20 / +85 |
Indoor/Outdoor Riser
Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNR riser cable, when using indoor/outdoor riser cable indoors, it is intended for vertical runs between floors or non-plenum applications.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
N/A | .275 |
Type. Atten. (dB/km) | 3.0/1.0 |
Max. Atten. (dB/km) | 3.75/1.5 |
Bandwidth (Mhz*km) Corning# | 220/500 InfiniCor 300 385/500 InfiniCor 1000 |
Diameter (mm) | 6.3 |
Pull Load (N) Install/Operate |
1800/600 |
Bend Radius (cm) Install/Operate |
9.8/6.5 |
Buffer Size (um) | 900 |
Storage Temp. (°C) | -40 / +85 |
Operating Temp. (°C) | -20 / +85 |
Indoor/Outdoor Plenum
Indoor/Outdoor cable can withstand the strains of outdoor use but also meets the flammability requirements of indoor cables. Like OFNP plenum cable, when using indoor/outdoor plenum cable indoors, it is intended for horizontal runs within ceilings, air ducts, and where required by local fire code.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
N/A | .275 |
Type. Atten. (dB/km) | 3.0/1.0 |
Max. Atten. (dB/km) | 3.75/1.5 |
Bandwidth (Mhz*km) Corning# | 220/500 InfiniCor 300 385/500 InfiniCor 1000 |
Diameter (mm) | 6.3 |
Pull Load (N) Install/Operate |
1800/600 |
Bend Radius (cm) Install/Operate |
9.8/6.5 |
Buffer Size (um) | 900 |
Storage Temp. (°C) | -40 / +85 |
Operating Temp. (°C) | -20 / +85 |
Aerial (Self-supporting)
Designed to be strung from poles outdoors, this cable has an internal stress member that protects the fibers from strain.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
N/A | .275 |
Attenuation (dB/km) | 3.5/1.5 |
Bandwidth (Mhz*km) | 200/500 |
Diameter (mm) | 9.5 |
Buffer Size (um) | 900 |
Storage Temp. (°C) | -70 / +85 |
Operating Temp. (°C) | -55 / +85 |
Direct Burial
Direct burial cable is intended for use in ducts, buried directly underground, or lashed aerial applications. It features an armor layer inside the jacket to help prevent damage.
Mode | Multimode |
---|---|
Core/Clad | 62.5/125 |
Max. Atten. (dB/km) | 3.25/1.0 |
Bandwidth (Mhz*km) | 220/500 |
Diameter (mm) | 13.46 |
Max. Installation Load (N) | 2700 |
Bend Radius (cm) Short Term/Long Term |
26.9/20.2 |
Storage Temp. (°C) | -50 / +80 |
Operating Temp. (°C) | -40 / +70 |